Denso RC5 Specifikace Strana 372

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 692
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 371
12-96
ST_ResetCompJLimit (Statement) [Ver.1.9 or later]
Function
Initializes the current limit under the compliance control (special compliance control
function statement) (exclusively designed for 6-axis robots).
Format
ST_ResetCompJLimit
Explanation
Initializes the current limit under the compliance control and set 0 to all axes.
Related Terms
ST_SetCompJLimit, ST_SetCompControl
Notes
(1) Execute this command in a TAKEARMed task that has obtained arm
semaphore. If this command is executed without arm semaphore obtained, Error
"21F7 Cannot take arm semaphore" will result.
Example
ST_ResetCompControl 'Disable the compliance control
ST_ResetCompJLimit 'Initialize the current limits
Zobrazit stránku 371