Chapter 17. Spread Spectrum Communication (BHT-7500S only)
400
17.4.2 Detailed Function Specifications
Syntax: CALL "SS.FN3" 0 VERSION$
Description:
This function returns the SS.FN3 library version in VERSION$.
Parameters: (None)
Returned value: VERSION$: Version information, 7 characters, fixed length
Run-time errors:
Syntax: CALL "SS.FN3" 1 PARA%,DATA%
Description:
This function gets integer (DATA%) from the wireless block setting speci-
fied by PARA%.
Parameters: PARA% Setting number
Returned value: DATA% Integer read from the specified wireless block setting
Correspondence table:
Run-time errors:
Function #0 Get SS.FN3 version
Error code Meaning
F0h
Mismatch parameter number
F1h
Mismatch parameter type
F2h
Insufficient string variable storage area
Function #1 Get parameter value (integer) from the wireless block
Setting number
(
PARA%)
Description
Values for setting
(
DATA%)
Initial
value
1 Domain information 0 to 15 0
Error code Meaning
05h
Parameter out of the range
F0h
Mismatch parameter number
F1h
Mismatch parameter type